• Hxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher Equipment
  • Hxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher Equipment
  • Hxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher Equipment
  • Hxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher Equipment
  • Hxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher Equipment
  • Hxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher Equipment

Hxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher Equipment

Certification: CE, ISO
Installation
Method:
Vertical
Operation
Type:
Automatic
Medium Material: Mineral/Coal/Chemical/Concrete
Dust Collecting Method: Dry
Type: Cyclone Dust Collector
Customization:
Diamond Member Since 2024

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
HXMC-97
Filtered Air Volume(M³/H)
6750
Filter Area(M³)
75
Collection Efficiency%
99.5
Overall Size(L*W*H)mm
φ2500*2500*5780
Transport Package
Customized
Specification
Casting steel
Trademark
HENGSHENG
Origin
Shandong, China
HS Code
8421392990
Production Capacity
5000sets/Year

Product Description

Product Description
Cyclone dust collector is composed of intake pipe, exhaust pipe, cylinder, cone and ash bucket. Cyclone dust collector has simple structure, easy manufacturing, installation and maintenance management, low equipment investment and operating costs, and has been widely used to separate solid and liquid particles from the air stream, or to separate solid particles from the liquid. Under ordinary operating conditions, the centrifugal force acting on the particles is 5 to 2500 times that of gravity, so the efficiency of the cyclone is significantly higher than that of the gravity settling chamber. Based on this principle, a cyclone dust removal device with a dust removal efficiency of more than 90% has been successfully developed. In the mechanical dust collector, the cyclone dust collector is the most efficient one. It is suitable for the removal of non-viscous and non-fibrous dust, mostly used to remove particles above 5μm, and the parallel multi-tube cyclone dust collector device also has 80 ~ 85% dust removal efficiency for particles of 3μm. Selection of high temperature, abrasion and corrosion resistance of special metal or ceramic material structure of cyclone dust collector, can be operated at temperatures up to 1000ºC, pressure up to 500×105Pa conditions. From the technical and economic aspects, the pressure loss control range of cyclone dust collector is generally 500 ~ 2000Pa. Therefore, it belongs to the medium efficiency dust collector, and can be used for the purification of high temperature flue gas, is a widely used dust collector, more used in boiler flue gas dust removal, multi-stage dust removal and pre-dust removal. Its main disadvantage is that the removal efficiency of fine dust particles (< 5μm) is low.
Hxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher Equipment
 
Hxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher Equipment
Preparation
1, check whether the connection parts are firmly connected.
2, check the dust collector and flue, dust collector and ash hopper, ash hopper and ash discharging device, ash conveying device and other joint tightness, eliminate ash leakage, gas leakage phenomenon.
3. Turn off the baffle valve, start the fan, and start gradually after no abnormal phenomenon.

Technical requirements
1. Pay attention to the changes of easy to wear parts such as the inner wall of the outer cylinder.
2. When the temperature of dusty gas changes or the humidity decreases, pay attention to the adhesion, blockage and corrosion of dust.
3, pay attention to the change of pressure difference and exhaust smoke status. Because wear and corrosion will perforate the dust collector and lead to dust emission, the dust removal efficiency decreases, the exhaust smoke color deteriorates, and the pressure difference changes.
4, pay attention to the air tightness of each part of the cyclone dust collector, check the change of the cyclone gas flow and dust collection concentration.
Model Filtered air volume(m³;/h) Filter area(m³) Collection efficiency(%) Overall size(L*W*H)mm
HXMC-80S 12000 130 99.5 φ800*800*2980
HXMC-80 5800 70 99.5 φ800*800*2980
HXMC-97 6750 75 99.5 φ2500*2500*5780
HXMC-145 10080 112 99.5 φ3000*3000*5780
HXMC-221 15390 171 99.5 φ3500*3500*5780
 
Hxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher EquipmentHxmc-97 Industrial Cyclone Dust Collector for Steel/Cement/Crusher Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now